General characteristics:
- DINRAIL type central compensation unit 6 fuses IP 40.
- Bright 2X8 line LCD Display on a green background with continuous status display of basic functions (Selectable application, Compensation curve, Sensor temperatures & Relay status).
- Ambient temperature monitoring by external sensor type V-NTC1K5B.
- Installation water supply temperature monitoring by sensor type V-NTC1K5 or V-NTC1K5 Τ αcontact sensor on the pipe.
Sensor damage detection system.
Direct control of the Boiler and installation circulator.
Direct control of a Three-Way Mixing Valve and installation circulator.
Direct control of the Boiler and installation circulator with parallel DHW production.
Remote selection switch to differentiate the selectable curve in degrees Celsius (±5°C).
Remote ON-OFF switch selection for DHW production.
Option to select < Boiler maintenance > for cleaning from liquefaction or deposits in the combustion chamber.
- Full parameterization of the factory settings from an easy-to-use and understandable menu.
- 230 VAC power supply.
- Three dry contact Relay 6A/230 VAC – 30 VDC.
- Two outputs for PWM variable speed pumps.
- Installation on the wall or in a rail box.
Indicative diagrams of supported configurations